NEWS DETAILS

The main classification of air shower is human air shower and cargo air shower

日期:2024-12-04 10:27
浏览次数:293
摘要: The main classification of air shower is human air shower and cargo air shower The main classification of air shower room is human air shower room and cargo air shower room, air shower room channel and cargo channel four categories, people can be selected according to the function of the cleaning room, generally people use air shower room channel such cleaning equipment can let people and goods jointly clean, so as to better meet people's needs, this is also the classification of air s

The main classification of air shower is human air shower and cargo air shower

The main classification of air shower room is human air shower room and cargo air shower room, air shower room channel and cargo channel four categories, people can be selected according to the function of the cleaning room, generally people use air shower room channel such cleaning equipment can let people and goods jointly clean, so as to better meet people's needs, this is also the classification of air shower room, A cost-effective product.



Air shower

Some of the problems you need to pay attention to when using the air shower are revealed to know:

It is known that the air shower room is a necessary channel for people to enter and exit the clean room, which is very versatile, mainly used in electronic processing, medical and other industries, to remove the dust attached to the surface of the person, and to play the role of airlock. The air shower room is a purification equipment to prevent unpurified air from entering the clean area. Today, we mainly tell you what problems we need to pay attention to when using the air shower room?

1, air shower room electrical safety matters: first put the product in place before wiring, power operation, so as not to cause personal injury; Confirm whether the rated voltage and frequency of the product are consistent with the parameters of the input power supply, so as not to damage the electrical components and cause fire; The air shower fan is a three-phase 380v power supply, if the reverse connection will lead to a decrease in wind speed, at this time, just replace any two phases, you can resume normal work;



2, the air shower room operation safety matters: under normal atmospheric conditions, the air shower room source and end and the shell or exposed conductive part between the insulation resistance value should be greater than 20M, after the humidity test insulation resistance value should be greater than 2M; After connecting the power supply, the two doors are immediately interlocked, only one of the doors can be opened, and the two doors can not be forcibly opened at the same time, enter the air shower room, and after closing the door, the shower is immediately started; After blowing, the door to lock, can not force open the door, in the process of blowing, press the emergency stop switch, blowing immediately stop.



3, the air shower room basic safety matters: do not put the air shower room in the high-speed dust source and source; When cleaning the air shower room, do not use volatile oils, corrosive solvents, etc., to wipe the box; Do not scratch the panel, affecting the appearance; When installing the air shower room, pay attention to leaving maintenance space to facilitate the maintenance of high efficiency filters and fans;