【The LCD language chain manual air shower】
The LCD language chain manual air shower
一、Introduction
Air shower control system is mainly used for air shower room, shower room and automatic control of air shower channel.Can automatically realize the inside and outside the door interlock and unlock;Rev. Stop lighting;The human body function such as automatic induction and start-stop of the fan.Products in the automatic process related voice prompt, and have air shower time, QianHouMen unlock delay time, lighting the flexible function such as delay time is adjustable.
二、Motherboard mask schematic and buttons
A、Air shower control panel buttons:
1、Stop button: press the stop button at any time, the blue backlit LCD screen stop flashing, graphics and automatic fire lighting of all output, press again, system restore to its original state.This button is mainly used for inside and outside the door can't unlock, the wind cannot be automatically closed and other maintenance.
2、Air shower button:In the inside and outside the door is closed, presses the button, the manual system into the wind leaching process.This button is mainly used for gate magnetism, the infrared failure or fan maintenance.
3、Lighting buttons:Using the "lighting" button, can switch air shower indoor lighting.This button is mainly used for door sensor failure or maintenance of lamps and lanterns.
4、Up, down keys:In air shower before or after, through the air shower, cut key adjustment in the delay time.Enter the internal parameter is set to adjust or options.
B、The air shower light and digital tube display shows:
1、Air shower countdown display: the blue backlit LCD screen display, job value and displays the air shower time air shower time remaining, set menu, used to display menu parameters.
2、LCD screen outside door open graphics: when the outside door open, besides the door open graphics flashing (after can be used to check whether the outside door magnetic is normal).
3、LCD induction graphics: when the body into the induction zone, the induction the flashing (after-sales can be used to check whether the photoelectric switch is normal).
4、LCD screen inside door open graphics: when interior door open, the inside door open graphics flashing (after-sales can be used to check whether the inner magnetic normal).
5、LCD screen to drench graphics: -- spray graphics flashing, indicating the wind rain fan has been started automatically or manually.
6、LCD scram graphics: this stop graphics and flashing, indicator system in the stop state.
7、Graphic LCD lighting: lighting the graphics flashing, indicating lights start, can according to the button to turn off or start again.
三、Vice board wiring diagram input and output terminal interface specifications:
三、Instructions for
A、Air shower work parameters set:
1、System is equipped with an external parameter Settings: air shower time setting and external parameter Settings can be directly modified with the cut on the key.
2、System has six internal parameter Settings, four of them within time and 2 as the feature parameters, set up internal parameter setting should be continuous press the stop button for 30 seconds into the internal state of parameter Settings.Setup, abrupt stop button to use as a set key, the wind leaching keys used as page button, adjust the up and down keys are set parameters can be adjusted.
3、Continuous press the stop button after 30 seconds into the state of parameter Settings, such as press air shower, LCD screen leaching time position will, in turn, circulating according TI, TO, TC, TL, Td, Tn six parameters.Corresponding: TI outside door unlocked delay setting, TO the inner time setting, TC after air shower time unlock setting, TL lighting time delay setting, Td function setting, Tn door swaps set, complete set, 5 seconds if there is no automatic storage operation and exit the Settings.
B、Air shower working parameters set operation:
1、Air shower time setting: this option for external time parameters, in the air shower before or after, hold down the raise or lower key, through the upper and lower adjusting button can change after the wind rain delay time, the adjusting range 1-99 seconds, and by the LCD digital display, adjust after 5 seconds, the system automatically save the parameter values.
2、Outside door unlock delay set TI: this option for internal time, continuous press the stop button for 30 seconds, the system into the internal parameters setting, LCD display: TI, according to increase or reduce key again to view outside door unlock delay time, the unit is in seconds, according to increase or reduce keys can be adjusted from 0-99 seconds, press air shower and into the next option, 5 seconds is not save parameters exit the Settings button trigger system.
3、Interior door unlock time delay is set TO: after completion of outside door is set TO again in 5 seconds press the wind rain, into the interior door unlock delay set (TO), through the upper and lower adjusting button can view and adjusting time in 0-99 seconds.Press air shower and into the next option, 5 seconds is not save parameters exit the Settings button trigger system.
4、Air shower after the electric lock delay unlock setting TC:
After completion of lighting set up 5 seconds press the air shower, again into the electric lock delay unlock time setting (TL), through the upper and lower adjusting button can view and adjust the lighting in 0-99 minutes delay time.Press air shower and into the next option, 5 seconds is not save parameters exit the Settings button trigger system.
5、Lighting time delay setting TL:
Completion of delay electric lock unlock Settings, need again in 5 seconds press the wind rain, into the lighting time delay setting (TL), through the upper and lower adjusting button can view and adjust time in 0-60 minutes, 0-59 as the actual number of minutes.Press air shower and into the next option, 5 seconds is not save parameters exit the Settings button trigger system.
6、Set of Td feature set:
Set to 0 to ordinary, namely "- induction - blowing rain - that take the door to go out" process control;When set to 1 for no induction type, namely "the door - blowing tube - go out" process control;When set to 2 for one, namely "induction - blowing leaching process control.
7、Swap function set Tn door:
Door swap function has two state of 0 s and 1 s, is set to 0 is normal, is set to 1 for swaps;Such as front and back door when installation the wrong, is set to 1, you can swap to work properly.
C、Conventional air shower work process:
1、Into the clean area:
1.1、Outside personnel entering a clean area to open the door, interior door electric lock automatically locked in wind rain indoor purify air flows into the clean area, air shower lights lit, outside work indicator.
1.2、After entering the air shower close the outside door, voice: "hello, please stand in the induction zone".System infrared probe began to detect someone like someone is detected, the system is transferred to the wind leaching process.
1.3、After entering the air shower close the outside door, voice: "hello, please stand in the induction zone".System infrared probe began to detect someone like someone is detected, the system is transferred to the wind leaching process.
1.4、Such as system time to detect after the door shut out someone, air shower system inside and outside the door unlocked, return to standby mode, infrared will continue to test, if someone is detected, the inside and outside the locked door, air shower to start the wind rain.
1.5、Wind leaching process, some press raised, cut, and the lighting switch, voice prompts: "working, please don't touch the switch".
1.6、Wind leaching process, when someone according to the urgent stop switch will end the wind rain.Press stop to cancel again stop state.
1.7、The wind after the rain, interior door unlocking, voice prompt: "pour over, please exit from the back door".
1.8、Shut out of the air shower and interior door, after system back to the initial state, waiting for the next use.
1.9、After wind rain, interior door unlocked.The personnel within the prescribed time inside didn't leave the air shower, system default may have left, return to standby mode automatically.
1.10、Lights light up, time is not fire again, automatically go out.
2、Leave the clean area:
2.1、Open the inner door, electric door lock locking outside, the wind leaching room lights light up, work indicator.
2.2、People into the air shower, close the interior door, the system began to detect whether someone in air shower, such as detected no one within the prescribed time, both inside and outside the door unlocked.
2.3、If someone is detected, the system for personnel outside the open doors, interior door lock, when close the outside door, return to original state system.
2.4、In case of special circumstances, people can choose to return to clean areas, on the personnel system for open inside and outside the door electric locking, when close the interior door, return to original state system.
2.5、Outside the door open, such as less than one time detection, if the open outside the door first, system is to enter the clean area process;If the first open the inner door, leave clean net system in process.
2.6、Lights light up, time is not fire again, automatically go out.
五、Use notice:
1、Panel size: 244 * 125 (MM), requires opening size: add 1-2 MM per side.
2、Products use door magnetic switch requirement: closed contact closure, off contact when opening the door.
3、Products using infrared induction switch requirement: 12 VDC power supply, no person off contact, when someone contact closure.