摘要:Medical transfer windows are usually used in negative pressure isolation wards or clean operating rooms to reduce the number of door openings and reduce indoor pollution from the outside world. Negative pressure isolation wards are usually equipped with medical transportation windows to transport medical and daily necessities to meet the daily needs of patients in the ward. At the same time, it can reduce the number of medical staff entering and leaving the negative pressure ward, reduce the cha
Medical transfer windows are usually used in negative pressure isolation wards or clean operating rooms to reduce the number of door openings and reduce indoor pollution from the outside world. Negative pressure isolation wards are usually equipped with medical transportation windows to transport medical and daily necessities to meet the daily needs of patients in the ward. At the same time, it can reduce the number of medical staff entering and leaving the negative pressure ward, reduce the chance of infection, and protect the health of medical staff. As a good "auxiliary" to the clean room, it keeps the virus far away from you!
As an auxiliary equipment of the clean room, the transfer window is mainly used for the transfer of small objects between the clean area and the clean area, and between the non-clean area and the clean area, so as to reduce the number of door openings in the clean room and reduce the pollution of the clean area. In order to maintain a clean and sterile environment, ultraviolet germicidal lamps are generally installed. Before each use, turn on the UV lamp for disinfection, and turn on the UV lamp during use. Double-door closed interlocking is adopted, and ultraviolet disinfection lamp holders are installed near the inner or outer wall between the double windows. Configure the double-door interlocking function as required to reduce direct contact inside and outside the ward. The ultraviolet disinfection lamp holder required here is also to prepare for the disinfection of the delivery items in the delivery window. It is the difference between the delivery window in the negative pressure ward and the delivery window in other areas.

 

Transfer window


1. The two doors of the transparent window should be kept closed during use. If there is a through window with a live lighting system, plug in the power plug first and turn on the 220V/50Hz power supply.
2. Turn on the power switch of the ultraviolet germicidal lamp when it is necessary to disinfect and sterilize the objects passing through the window. At this time, the ultraviolet germicidal lamp is on, and the sterilization treatment is carried out according to the regulations.
3. During use, open a door of the transfer window, and the other side will automatically lock, so when transferring items, first open the door, send the items to be transferred to the transfer window, close the stainless steel transfer window door . After sterilization, the door on the other side can be opened. Similarly, after taking out the delivered items, the staff should close the stainless steel door immediately, so as not to affect the items delivered next time.
4. Frequently clean the inside of the window and replace the UV tube regularly.
5. When materials are transferred from a non-clean area to a clean area, the surface of the material should be cleaned first.
6. When the transfer window interlocking device fails to work normally, it should be repaired in time, otherwise it cannot be used.