摘要:After thawing platelets, they must be kept in a constant temperature of 20℃~ 24℃ during the process of waiting for injection. Platelet storage box is made in accordance with this requirement of equipment, when the thawing of platelets on the internal storage shelf, can continuously output a range of 50 mm, frequency of 60 weeks/point or so in a succession of around, horizontal oscillation, solve the problem of safe storage of platelets. Platelet preservation box is divided into uppe..
After thawing platelets, they must be kept in a constant temperature of 20℃~ 24℃ during the process of waiting for injection. Platelet storage box is made in accordance with this requirement of equipment, when the thawing of platelets on the internal storage shelf, can continuously output a range of 50 mm, frequency of 60 weeks/point or so in a succession of around, horizontal oscillation, solve the problem of safe storage of platelets.



Platelet preservation box is divided into upper and lower two parts; The upper layer is storage box, the lower layer is instrument cabinet and refrigeration system, temperature control adopts new intelligent microcomputer control system, LCD LCD display temperature, high precision, no overadjustment; RS485 communication interface is used to connect computer, display and print temperature and time data by computer, and provide strong guarantee for data storage and playback in test process; The door of the incubator is designed as a compound door, and the inner door is made of tempered glass, which can directly observe the culture in the working room. The outer door adopts magnetic door seal with good sealing.



There is no room for error, so what should be taken care of when using a platelet box?



1. Use position: when put into the use position, there should be a certain gap between the left and right sides of the platelet storage box to facilitate the opening or disconnection of the power switch, and there should be a 20cm gap on the back to ensure effective heat dissipation of the condenser, and lock the front wheel to fix the machine.



2. Working cycle: can work continuously for a long time.



3. Power supply: insert the power plug into the three-core power socket with protective grounding, and connect the power supply.



4. Electrification: press down the power switch "I" on the panel of the electrical control box to electrify the whole machine.



5. Boot display: after power on for several seconds, display the current temperature value in the storage box.



6. Oscillation: switch the switch ON the oscillation trolley to "ON" to start the oscillation trolley; Turn OFF the oscillating trolley