Product
- Laminar flow cabinet
-
Biological safety cabinet
-
Fume hood
-
Pass box
-
air shower
- Autoclave/Steam sterilizer
- Incubator
-
Drying Oven
-
Clean sampling vehicle
-
Medical hand washing sink
-
Weighing booth
-
Particle counter
-
Air sampler
-
Muffle furnace
-
water distiller
-
ozone generator
-
water bath
-
Air purifier
-
vacuum pump
-
Colony counter
-
microcentrifuge
-
Pen PH meter
-
Vortex mixer
-
Anemometer
-
others
-
Glass bead sterilizer
NEWS DETAILS
Precautions for the use of embedded flat door pass box in clean rooms:
日期:2024-10-08 17:05
浏览次数:279
摘要:Precautions for the use of embedded flat door transfer windows in clean rooms:
1. Materials entering and leaving the clean area must be strictly separated from the flow channel, and enter and exit through the special channel for materials in the production workshop.
2. When the material enters, the raw and auxiliary materials will be unpacked by the person in charge of the preparation class or the surface will be cleaned, and then sent to the temporary storage room of raw materia
Precautions for the use of embedded flat door transfer windows in clean rooms:
1. Materials entering and leaving the clean area must be strictly separated from the flow channel, and enter and exit through the special channel for materials in the production workshop.
2. When the material enters, the raw and auxiliary materials will be unpacked by the person in charge of the preparation class or the surface will be cleaned, and then sent to the temporary storage room of raw materials and auxiliary materials in the workshop through the transfer window; It is sent to the inner package room through the transfer window. The workshop integrator handles the material handover with the person in charge of the preparation and internal packaging processes.
3. When passing through the transfer window, the regulations of "one opening and one closing" of the inner and outer doors of the transfer window must be strictly implemented, and the two doors cannot be opened at the same time. Open the outer door and put the material in, then close the door first, then open the inner door to take out the material, close the door, and so on.
4. When the materials in the clean area are sent out, the materials should be transported to the relevant material intermediate station first, and the materials should be moved out of the clean area according to the reverse procedure when the materials entered.
5. All semi-finished products shipped from the clean area must be sent from the transfer window to the external temporary storage room, and then transferred to the outer packaging room through the logistics channel.
6. Materials and wastes that are very likely to cause pollution should be transported from their dedicated transfer windows to non-clean areas.
7. After the material is in and out, the site of each cleaning room or intermediate station and the sanitation of the transfer window should be cleaned up in time, the inner and outer access doors of the transfer window should be closed, and the cleaning and disinfection work should be done well.
Flat door transfer window structure
Embedded flat door transfer window | What functions does the pharmaceutical factory flat door transfer window have?
The transfer window of the flat door is managed according to the cleanliness level of the higher-level clean area connected to it. For example, the transfer window connected between the coding room and the filling room should be managed according to the requirements of the filling room. After get off work, the operator in the clean area is responsible for wiping the interior surfaces of the transfer window clean, and turning on the ultraviolet sterilization lamp for 30 minutes.
1. Materials entering and leaving the clean area must be strictly separated from the flow channel, and enter and exit through the special channel for materials in the production workshop.
2. When the material enters, the raw and auxiliary materials will be unpacked by the person in charge of the preparation class or the surface will be cleaned, and then sent to the temporary storage room of raw materials and auxiliary materials in the workshop through the transfer window; It is sent to the inner package room through the transfer window. The person in charge of the workshop synthesis, preparation and internal packaging process handles the material handover.
3. When passing through the transfer window, the regulations of "one opening and one closing" of the inner and outer doors of the transfer window must be strictly implemented, and the two doors cannot be opened at the same time. Open the outer door and put the material in, then close the door first, then open the inner door to take out the material, close the door, and so on.
4. When the materials in the clean area are sent out, the materials should be transported to the relevant material intermediate station first, and the materials should be moved out of the clean area according to the reverse procedure when the materials entered.
5. All semi-finished products shipped from the clean area must be sent from the transfer window to the external temporary storage room, and then transferred to the outer packaging room through the logistics channel.
6. Materials and wastes that are very likely to cause pollution should be transported from their dedicated transfer windows to non-clean areas.
7. After the material is in and out, the site of each cleaning room or intermediate station and the sanitation of the transfer window should be cleaned up in time, the inner and outer access doors of the transfer window should be closed, and the cleaning and disinfection work should be done well.
1. Materials entering and leaving the clean area must be strictly separated from the flow channel, and enter and exit through the special channel for materials in the production workshop.
2. When the material enters, the raw and auxiliary materials will be unpacked by the person in charge of the preparation class or the surface will be cleaned, and then sent to the temporary storage room of raw materials and auxiliary materials in the workshop through the transfer window; It is sent to the inner package room through the transfer window. The workshop integrator handles the material handover with the person in charge of the preparation and internal packaging processes.
3. When passing through the transfer window, the regulations of "one opening and one closing" of the inner and outer doors of the transfer window must be strictly implemented, and the two doors cannot be opened at the same time. Open the outer door and put the material in, then close the door first, then open the inner door to take out the material, close the door, and so on.
4. When the materials in the clean area are sent out, the materials should be transported to the relevant material intermediate station first, and the materials should be moved out of the clean area according to the reverse procedure when the materials entered.
5. All semi-finished products shipped from the clean area must be sent from the transfer window to the external temporary storage room, and then transferred to the outer packaging room through the logistics channel.
6. Materials and wastes that are very likely to cause pollution should be transported from their dedicated transfer windows to non-clean areas.
7. After the material is in and out, the site of each cleaning room or intermediate station and the sanitation of the transfer window should be cleaned up in time, the inner and outer access doors of the transfer window should be closed, and the cleaning and disinfection work should be done well.
Flat door transfer window structure
Embedded flat door transfer window | What functions does the pharmaceutical factory flat door transfer window have?
The transfer window of the flat door is managed according to the cleanliness level of the higher-level clean area connected to it. For example, the transfer window connected between the coding room and the filling room should be managed according to the requirements of the filling room. After get off work, the operator in the clean area is responsible for wiping the interior surfaces of the transfer window clean, and turning on the ultraviolet sterilization lamp for 30 minutes.
1. Materials entering and leaving the clean area must be strictly separated from the flow channel, and enter and exit through the special channel for materials in the production workshop.
2. When the material enters, the raw and auxiliary materials will be unpacked by the person in charge of the preparation class or the surface will be cleaned, and then sent to the temporary storage room of raw materials and auxiliary materials in the workshop through the transfer window; It is sent to the inner package room through the transfer window. The person in charge of the workshop synthesis, preparation and internal packaging process handles the material handover.
3. When passing through the transfer window, the regulations of "one opening and one closing" of the inner and outer doors of the transfer window must be strictly implemented, and the two doors cannot be opened at the same time. Open the outer door and put the material in, then close the door first, then open the inner door to take out the material, close the door, and so on.
4. When the materials in the clean area are sent out, the materials should be transported to the relevant material intermediate station first, and the materials should be moved out of the clean area according to the reverse procedure when the materials entered.
5. All semi-finished products shipped from the clean area must be sent from the transfer window to the external temporary storage room, and then transferred to the outer packaging room through the logistics channel.
6. Materials and wastes that are very likely to cause pollution should be transported from their dedicated transfer windows to non-clean areas.
7. After the material is in and out, the site of each cleaning room or intermediate station and the sanitation of the transfer window should be cleaned up in time, the inner and outer access doors of the transfer window should be closed, and the cleaning and disinfection work should be done well.