摘要: As the auxiliary machine and equipment of the clean room, the transfer window is mainly used to transfer small objects between the clean area and the clean area, and between the non-clean area and the clean area, so as to reduce the times of opening and closing the door. It opens a line for the clean room. Safe passage for items. The frequency of the clean room greatly reduces the environmental pollution in the clean area. It is widely used in micro high-tech, laboratories, pharmaceutical co

As the auxiliary machine and equipment of the clean room, the transfer window is mainly used to transfer small objects between the clean area and the clean area, and between the non-clean area and the clean area, so as to reduce the times of opening and closing the door. It opens a line for the clean room. Safe passage for items. The frequency of the clean room greatly reduces the environmental pollution in the clean area. It is widely used in micro high-tech, laboratories, pharmaceutical companies, hospitals and clinics, food manufacturing, LCD, and hardware factories, all of which must be air filtered.
1. Mechanical equipment self-locking interlocking equipment: Interlocking is completed internally by mechanical equipment. When one door is open, the other cannot be opened. Before opening another door, be sure to close the other door.
2. Electronic equipment self-locking interlocking equipment: internally select integrated circuit chips, magnetic locks, operation panels, display lights, etc. to complete the interlocking. When one door is opened, the open/close indicator of the other door does not light up, so it prompts that the door cannot be opened. In addition, the magnetic lock posture completes the interlock. When the door is closed, the magnetic lock of the other door starts to work, and the other indicator light is on, indicating that the other door can be opened.

 

Transfer window


In the process of using the transfer window, when the raw materials enter and exit the clean area, they must be strictly separated from the human flow channel and the commodity circulation channel, and enter and exit through the special safe channel for raw materials in the production line. When the raw materials arrive, the raw and auxiliary materials are unpacked or cleaned by the organization personnel in charge of the process flow of the configuration group, and then sent to the raw and auxiliary material storage room of the production workshop through configuration. Transfer window; the outer packing box of the inner packing materials is taken out from the outer storage room and sent to the inner box. When transferring, you must strictly abide by the “one open and one closed” requirement for the inside and outside doors, and two doors cannot be opened separately.
When the raw materials in the clean area are sent out, the raw materials are transported to the relevant raw material intermediate station, and the clean area is removed according to the reverse procedure of the raw material arrival. All semi-finished products processed and transported from the clean area are sent from the transfer window to the external storage room, and then transported to the external packing box room through the safe freight logistics channel. The raw materials and wastes that are likely to cause environmental pollution should be transported to the unclean area from its dedicated transshipment window. After the raw materials enter and exit, the cleaning tank or the site of the central station should be cleaned immediately, and the internal and external safety access doors should be closed for disinfection and sterilization. To operate in accordance with the following specifications.
1. Use 0.5% sodium hypochlorite solution or 5% iodophor disinfectant to scrub the items to be shipped.
2. Open the doors on both sides of the delivery window, quickly put in the delivery, disinfect with 0.5% sodium hypochlorite solution, and close the doors on both sides of the window.
3. Turn on the ultraviolet germicidal lamp in the transmission window, and irradiate ultraviolet rays to the transmitted object for no less than 15 minutes.
4. Notify the tester or the sky obstacle system software personnel to open the side door and take out the object.
5. Close the side door.