NEWS DETAILS

About the maintenance and maintenance of the air shower

日期:2024-03-29 06:32
浏览次数:296
摘要:The air shower room is the necessary channel to enter the clean room, also called air shower, clean air shower room, clean air shower room, air shower room, blowing shower room, air shower door, dust room, blowing shower room, air shower Channel, air blowing room. It can reduce the pollution problems caused by entering and leaving the clean room. Recently, many users have reported that the failure of the air shower room will not be dealt with. Fuxia simply sorted out the following 4 points. 1.
The air shower room is the necessary channel to enter the clean room, also called air shower, clean air shower room, clean air shower room, air shower room, blowing shower room, air shower door, dust room, blowing shower room, air shower Channel, air blowing room. It can reduce the pollution problems caused by entering and leaving the clean room. Recently, many users have reported that the failure of the air shower room will not be dealt with. Fuxia simply sorted out the following 4 points.
1. When the air shower room has been used for a period of time, if the wind speed is very low, immediately check whether the filter in the air shower room can accumulate too much dust, and if it is a new one, replace the filter. Usually it is necessary to exchange it every 1-6 months, and the high-efficiency filter is usually exchanged every 6-12 months.
2. If the air shower room cannot automatically sense the blowing, check the light sensor system in the lower right corner of the air shower room to see if the light sensor equipment is correct.
If the emergency stop button is red, it means that the air shower room will not blow, and you only need to press the emergency stop button from the beginning to work normally.
3. When the air shower is not operating, first check whether the emergency switch of the outer box of an inferior shower door can be blocked. If it is blocked, press it quietly with your hand and rotate it to the right to release it.
4. The fan in the air shower room is reversed. Perhaps the wind speed in the air shower room is very small. It is necessary to check whether the 380V three-phase four-wire circuit can be reversed. If the line source of the air shower is reversely connected, the lighter one will cause the fan in the air shower room to not operate or the wind speed of the reverse air shower room will decrease, and the heavy one will burn the circuit board of the entire air shower room.

The structure of the air shower


The maintenance and maintenance of the air shower is directly related to the work efficiency of the air shower and the service life of the air shower. Let me share with you the maintenance methods of the air shower.
1. When installing and positioning the air shower room, do not move it at will. Rectify it. If you need to change the displacement, you must seek the guidance of professionals and manufacturers. If you need to change the displacement, you must re-calibrate the ground level to prevent the door frame from deforming and affect the normal operation of the air shower room.
2. The equipment location and environment of the air shower room should be well ventilated and dry.
3. Do not touch or use all control switches under normal working conditions of the air shower room.
4. In the sensing area of people or goods, the system can enter the blowing and showering process after receiving the induction.
5. Do not transport large items from the air shower room to avoid damage to the surface and electrical controls.
6. Air shower indoor and outdoor panels, do not hit by foreign objects to avoid scratches.
7. The door of the air shower room is electronically interlocked. When one door is opened, the other door is automatically locked. When the system is running, do not force any door to open, and do not force open two doors at the same time.
8. The blowing time has been set, please do not adjust it at will.
9. The air shower room needs to be managed by the responsible person, and the primary filter should be replaced regularly on time. The replacement is generally 3-6 months per time, depending on the cleanliness of the surrounding environment.
10. When using the air shower room, pay attention: the door should be opened and closed gently.
11. Replace the high-efficiency filter of the air shower room in an average of 2 years.
12. In case of failure in the wind shower room, report to professional maintenance personnel for repair in time.