How to maintain the air cover capture hood?
日期:2024-09-19 04:32
浏览次数:393
摘要:How to maintain the air cover?
The hood can be used to make accurate measurements over a long period of time. Some parts can be cleaned periodically. Please follow the instructions below.
1. Prepare the cover
It can be cleaned with a flexible cleaner and cold water. When cleaning, do not let the air volume cover encounter with sharp Angle and sharp edge of the object, extensive cleaning will cause damage to the cover.
2. Micromanometer
The micro pressure gauge body, displ.
How to maintain the air cover?
The hood can be used to make accurate measurements over a long period of time. Some parts can be cleaned periodically. Please follow the instructions below.
1. Prepare the cover
It can be cleaned with a flexible cleaner and cold water. When cleaning, do not let the air volume cover encounter with sharp Angle and sharp edge of the object, extensive cleaning will cause damage to the cover.
2. Micromanometer
The micro pressure gauge body, display screen and key can be swabbed with wet cloth and soft cleaning agent solution, do not put the instrument into water, wipe the instrument before use.
3. Speed probe array
If it is found that the air flow detection head of the compound joint is blocked by dust or other things, please wipe it with a wet cloth. Do not apply too much force to the joint array cleaning. If any part of the array is broken, please contact the aftermarket.
4. If the hood itself or storage needs cleaning, wipe with a soft cloth coated with isopropyl alcohol or a flexible cleaning agent. If the cover is cracked, it should be replaced or repaired. Tape can be attached to both sides of the crack for temporary repair. Replace the damaged cover or make a cover of different size. Please contact the manufacturer.
The hood can be used to make accurate measurements over a long period of time. Some parts can be cleaned periodically. Please follow the instructions below.
1. Prepare the cover
It can be cleaned with a flexible cleaner and cold water. When cleaning, do not let the air volume cover encounter with sharp Angle and sharp edge of the object, extensive cleaning will cause damage to the cover.
2. Micromanometer
The micro pressure gauge body, display screen and key can be swabbed with wet cloth and soft cleaning agent solution, do not put the instrument into water, wipe the instrument before use.
3. Speed probe array
If it is found that the air flow detection head of the compound joint is blocked by dust or other things, please wipe it with a wet cloth. Do not apply too much force to the joint array cleaning. If any part of the array is broken, please contact the aftermarket.
4. If the hood itself or storage needs cleaning, wipe with a soft cloth coated with isopropyl alcohol or a flexible cleaning agent. If the cover is cracked, it should be replaced or repaired. Tape can be attached to both sides of the crack for temporary repair. Replace the damaged cover or make a cover of different size. Please contact the manufacturer.