- Laminar flow cabinet
-
Biological safety cabinet
-
Fume hood
-
Pass box
-
air shower
- Autoclave/Steam sterilizer
- Incubator
-
Drying Oven
-
Clean sampling vehicle
-
Medical hand washing sink
-
Weighing booth
-
Particle counter
-
Air sampler
-
Muffle furnace
-
water distiller
-
ozone generator
-
water bath
-
Air purifier
-
vacuum pump
-
Colony counter
-
microcentrifuge
-
Pen PH meter
-
Vortex mixer
-
Hardness tester
-
Double Cup disintegrator
-
Dissolution Tester
-
Powder densimeter
-
Disc polarimeter
-
Magnatic stirer with heater
-
Anemometer
FX-182 medical mask synthetic blood penetration tester
The synthetic blood penetration tester for surgical masks is mainly used to determine the resistance of surgical masks to the penetration of synthetic blood under different test pressures. It can also be used to determine the resistance of other coating materials to the penetration of blood.
During the test, a certain amount of synthetic blood was sprayed horizontally to one side of the mask at a certain pressure and distance, and the penetration of synthetic blood on the other side of the mask was observed.
The device is used for the anti-synthetic blood penetration ability of medical surgical masks, mainly used in the field of medical protective products, and can also be used for the determination of other textile coating materials.
Its application fields include but are not limited to:
Manufacturer of medical masks;
Metrology verification department;
Research institutes;
Commodity inspection or quality control department of the manufacturer;
Third-party testing platform;
Quality supervision and market supervision and inspection units in various places;
GB 19083-2010 Medical protective mask technical requirements, 5.5 synthetic blood penetration barrier performance
YY / T 0691-2008 protective equipment for infectious pathogens, medical masks, synthetic blood penetration resistance test method (fixed volume, horizontal injection)
YY 0469-2011 Technical requirements for medical surgical masks Blood penetration test device
ISO 22609: 2004 protective equipment for infectious pathogens, medical masks, test method for penetration of synthetic blood (fixed volume, horizontal injection)
ASTM F1862-07 Standard Test Method for Penetration Resistance of Synthetic Blood of Medical Masks (Fixed Volume, Horizontal Injection)
l lThe mask fixture is a metal human head model, which can fully simulate the actual use state of the mask.
l lThe metal human head mold can rotate at a certain angle, which is convenient for sample clamping.
l l Special spray control device can spray a certain volume of synthetic blood within the controlled time.
l l The instrument adopts an air source that can provide (700 ± 25) kPa stable air pressure, which is not affected by the space of the test site.
l lIt can simulate the liquid ejection speed corresponding to human blood pressure 10.6kPa, 16.0 kPa, 21.3 kPa (namely 80mmHg, 120mmHg, 160mmHg) for testing.
l l There is a fixed target plate, which can block the high-pressure part of the sprayed liquid flow, and only let the steady-state flow part be sprayed on the area sample, which increases the accuracy and repeatability of the test.
l lThe instrument adopts imported special aluminum brushed panel with metal buttons, which is sensitive to operation and not easy to damage.
l lThe 7-inch color touch screen displays the test parameters, and the menu-type operation mode is as convenient as a smartphone.
l lThe core control components adopt STMicroelectronics 32-bit multi-function motherboard.
l lThe instrument code adopts 304 stainless steel, which is durable, neat and clean in appearance. ;
testing method |
Synthetic blood penetration test |
Spray distance |
300mm~310mmAdjustable |
Needle inner diameter |
0.84mm |
Jet velocity |
450cm/s、550cm/s、635cm/s % |
Standard synthetic blood formula |
|
Sodium carboxymethyl cellulose CMC, medium viscosity |
2g |
Tween 20 |
0.06g |
Sodium chloride analytical grade |
4.5g |
Methylisothiazole MIT |
0.5g |
Amaranth red dye |
1.0g |
Distilled water |
Add to 1L |